COOL/HEAT/DRY/FAN mode operation procedure
Air flow direction adjustment procedure. Page 10
Program changing procedure
Set the new program.
The operation program can also be set or changed when
the air-conditioner is not in operation.
Aim the remote control at the air-conditioner.
Press the MODE select button.
Move the [ mark] to the desirable operation position.
HE type:
(Cool), (Heat), (Dry)
CE type:
(Cool), (Fan), (Dry)
If the air-conditioner is not operating
Press the ON/OFF button.
Press the TEMP button.
Press or button for the desired temperature.
Standard
4
3
To stop: Press the ON/OFF button.
Air is not blown out during the operation.
Page 20
NOTE
2
1
Air-conditioner operating conditions
Use within the following operational range. Operating outside of this range may result in the protection devices being activated, preventing the
unit from working.
Cooling operation Heating operation
Outside temperature Approximately 21 to 43 °C Approximately -5 to 21 °C
Inside temperature Approximately 21 to 32 °C Approximately 15 to 30 °C
Below approximately 80%
The long-term use of the unit with a humidity level
Inside humidity
exceeding 80% may result in condensation forming on the
surface of the indoor unit, leading to water drips.
Characteristics of HEAT mode operation
Mechanism and capacity of HEAT mode operation
Mechanism
The unit draws in heat from the cold outside air, transfers it indoors and heats the room. The heating capacity of the heat pump mechanism decreases
when the outside air temperature gets colder.
The hot air circulation system takes a while before warming up the room temperature.
If the outside temperature becomes extremely low, it would be better to use an additional source of heating.
Defrosting
If the outside temperature becomes low and humidity is high, the heat exchanger in the outdoor unit may frost over, which prevents efficient heating.
If this happens, the automatic defroster is activated and during defrosting the heating operation stops for 5 to 10 minutes.
Both indoor and outdoor fans stop and the RUN light (green) blinks slowly (1.5 sec. ON, 0.5 sec. OFF) during defrosting.
The outdoor unit may give off some steam during defrosting. This is to help the defrosting process and is not a defect.
The HEAT operation resumes as soon as defrosting has been completed.
Press the FAN SPEED button
Set the fan speed as desired.
COOL
DRY
HEAT
26°C~28°C21°C~24°C
FAN
——22°C~24°C